(30)
Position hose guard (40) in recessed channel of bed behind condenser hose hole.
(31)
Using hose guard (40) as a template, drill 1/4 inch diameter hole in bed.
(32)
From underneath vehicle, insert bolt (41) and washer (42) through hose guard (40) and
bed.
(33)
Secure with locknut (43).
39
2-1.2
Installation of Air Conditioning Kit to M1097A2 with GSIE Add-on-Armor (Cont’d).
b. Install Evaporator and Condenser (Cont’d)
Figure 2-90.
Condenser Hose Hole (Two-Door)
Figure 2-91.
Hose Guard
(29) Two-door vehicles only:
a. Drill a 1.25 inch diameter hole (39) for condenser hose in transmission tunnel, near
driver side vertical condenser mount angle.
b. De-burr hole.
43
41
42
40


Back to Top