TB 9-3950-253-13&P
Change 1
0007-28
0007
STOW LIFT FRAME – CONTINUED
WARNING
Keep hands below top plate of control panel and completely away from lift frame locking
plate during loading/unloading of lift frame. Failure to follow this warning may result in
injury or death to personnel.
NOTE
For HEMMT M1120A4 only, if locking plates are misaligned, deflate and inflate suspension
air bags (TM 9-2320-326-14&P).
3. Press and hold RETRIEVE button (Figure 40, Item 1). As soon as stowage guide (Figure 40, Item 3) has
stopped tilting rearward, release button.
4. Stowage guide (Figure 40, Item 3) will be positioned under stowage rollers on lift frame (Figure 40, Item 2).
NOTE
•
Do not release DOWN button until hook arm stops.
•
Press UP and DOWN button as required to align locking plate with stowage assembly.
5. Press and hold DOWN button (Figure 40, Item 4). As soon as hook arm stops moving, release button.
Figure 40.
Lift Frame Positioned on Stowage Guide.
07
467-170
2
1
3
4