TM 5-5420-202 -20-2
ENGINE OIL COOLER FLUID PUMP CONNECTOR REPLACEMENT (Sheet 4 of 4)
5.
6.
7.
8.
Using 1-1/2 inch wrench, install hose
(E) to fitting (F).
Using screwdriver and 3/8 inch wrench,
install clamp (G) on hose (E) if removed
during disassembly.
Position new sealing washer (H) over vent
hole.
Using 9/16 inch wrench install and tighten
vent capscrew (J) through washer (H).
9.
Using socket and torque wrench, tighten
drain valve (K) to a minimum of 150 lb-
in. (17 NŽm). Do not overtighten.
10.
11.
12.
13.
14.
Perform ground hop (page 5-25). Run engine
at idle until oil temperature is in normal
operating range (TM 5-5420-202-10).
Shut down engine and wait 5 minutes.
Check oil level, add oil as required
(LO 5-5420-202-12).
Disconnect ground hop kit (page 5-40).
Install powerplant (page 5-14).
End of Task