TM 9-1240-401-34&P
7
Install M15 quadrant on quadrant mounting fixture
(5) (fig. C-12, appx C) with four bolts.
8
Position quadrant mounting fixture (5) on drill press
table with M15 quadrant placed in upright position.
9
Using cross-level knob (6), adjust cross-level bubble
in fire control level (7) until bubble centers.
10
Reposition quadrant mounting fixture (5) with
elevation quadrant facing upward.
11
Drill with a number 13 drill bit and ream for a 3/16-
inch straight pin (2).
12
Loosen screw (4) and remove shims previously
installed between bar (1) and housing (8). Seal over
screw (4) using sealing compound; (item 13, appx
B).
13
Aline holes drilled and reamed in bar (1) and
housing (6) and install straight pin (2).
14
Install screw (4) into recess of bar (1) but do not
tighten.
15
Remove M15 quadrant from quadrant mounting
fixture (5) and reinstall on test fixture adapter.
Change 1
5.1-65