6-4
TM 9-1240-401-34&P
6-8. GENERAL SUPPORT SYMPTOM INDEX
Troubleshooting
Procedure
(Page)
Mounting surface does not seat M42 periscope correctly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Windows are broken or cracked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Windows are fogged or condensation is present . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
6-9. GENERAL SUPPORT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
LOCATION
CORRECTIVE ACTION
1.
MOUNTING SURFACE (1) DOES NOT SEAT M42
PERISCOPE CORRECTLY.
Observe visually.
a. Clean mounting surface with
cleaning compound (item 3,
appx B).
b. Remove burrs with abrasive
cloth (item 4, appx B) dipped
in cleaning compound (item 3,
appx B).
2. WINDOWS (2) ARE FOGGED OR CONDENSATION IS
PRESENT.
Observe visually.
a. Purge and charge M42 periscope
(TM 750-116).
b. Repair M42 periscope (ref. para 6-10).
3. WINDOWS (2) ARE BROKEN OR CRACKED.
Observe visually.
Repair M42 periscope (ref. para 6-10).