TM-9-1240-401-34-P

TELESCOPE MOUNT M146: M118A2 AND M118A3; TELESCOPE MOUNT M145: M145A1; PANORAMIC TELESCOPE: M117 AND M117A2; FIRE CONTROL QUADRANT: M15; PERISCOPE: M42

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

JULY 1993

  TM-9-1240-401-34-P - Page 320 of 590

6-10
6-12. M42 PERISCOPE FINAL INSPECTION AND ADJUSTMENT-continued
a. SETTING UP INSPECTION FIXTURE - continued
12
13
14
15
16
17
18
19
View auxiliary telescope (5) vertical reticle line
through collimating telescope (7) and revolve auxil-
iary telescope (5) until image of vertical reticle line
is in coincidence with preplumbed vertical reticle
line of collimating telescope (7).
Using parallel bars, adjust height of collimating
telescope (7) to height of collimating projector (3)
on inspection fixture (1).
Place collimating telescope (7) in line with collimat-
ing projector (3).
View collimating projector (3) vertical reticle line
through collimating telescope (7) and revolve col-
limating projector (3) until image of vertical reticle
line is in coincidence with preplumbed vertical
reticle line of collimating telescope (7).
Using collimating projector (3) light source, autocol-
Iimate auxiliary telescope (5), using support (6)
adjusting screws (9), until reticle image is superim-
posed on image reflected by the reflecting mirror
(2).
Look through collimating projector (3) and autocol-
Iimate collimating projector using collimating pro-
jector (3) support screws (10), until reticle image is
superimposed on image reflected by reflecting mir-
ror (2).
Repeat steps 11 thru 15 to check that trueness of
retitles has not been disturbed.
Remove reflecting mirrors (2) from inspection fix-
ture (1).


Back to Top