7 Make sure pressure regulator valve (8) is closed
(fully counterclockwise). Then slowly open pres-
sure regulator valve (8) until 1 psi (0.07 Kg/cm
2
)
registers on low pressure gage (9).
a.
Charge M42 periscope for 10 seconds.
b. Turn pressure regulator valve (8) to off.
8 Apply a soap solution to all sealed joints and
screws. Observe low pressure gage and M42 peri-
scope for 5 minutes. If pressure drops or if bubbles
appear, repair as necessary (ref. para 6-10).
9 Remove hose assembly (6).
10 Install air valve cap (2).
6-13/(6-14 blank)