INSTALLATION - Continued
CAUTION
When filling cooling system, ensure drain valve on aftercooler is open. Failure to do so may
result in damage to equipment.
13.
Install tube (Figure 6, Item 3) and two hoses (Figure 6, Item 2) on aftercooler (Figure 6, Item 5) and turbocharger
(Figure 6, Item 4) with four clamps (Figure 6, Item 1).
M0051DAA
5
1
2
1
3
1
2
1
4
Figure 6.
Turbocharger Hoses and Clamps Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Fill coolant system. (WP
0287)
2.
Start engine and check turbocharger hoses. (TM 9-2320-272-10)
END OF TASK
END OF WORK PACKAGE