REMOVAL
WARNING
Do not disconnect air lines or hoses before draining air reservoirs. Small parts under pressure
may shoot out with high velocity. Failure to comply may result in injury or death to personnel.
NOTE
Tag lines and fittings for installation.
1.
Remove safety valve (Figure 1, Item 3) from reducing bushing (Figure 1, Item 2).
2.
Remove reducing bushing (Figure 1, Item 2) from tee fitting (Figure 1, Item 1).
2
3
1
M9400DAA
Figure 1.
Air Supply Line Safety Valve Removal.
END OF TASK
TM 9-2320-272-23-3
0460