TM-9-2320-272-23-3

TRUCK, 5-TON, 6X6, M939, M939A1, AND M939A2 SERIES TRUCKS (DIESEL)

TECHNICAL MANUAL; FIELD MAINTENANCE MANUAL; VOLUME 3 OF 5

SEPTEMBER 2012

  TM-9-2320-272-23-3 - Page 927 of 1469

REMOVAL
1.
Lift cover (Figure 1, Item 3) on fuse holder (Figure 1, Item 4) and pull out 15-AMP fuse (Figure 1, Item 2) from
fuse holder (Figure 1, Item 4).
2.
Disconnect jumper lead connector (Figure 1, Item 6) from red lead connector (Figure 1, Item 1) on ABS main
wiring harness (Figure 1, Item 7).
3.
Remove tiedown straps (Figure 1, Item 8) from jumper lead (Figure 1, Item 5) and harness lead
(Figure
1,
Item
11). Discard tiedown straps.
4.
Disconnect jumper lead connector (Figure 1, Item 13) from power lead connector (Figure 1, Item 12) on firewall
(Figure 1, Item 10).
5.
Remove grommet (Figure 1, Item 9) and route jumper lead (Figure 1, Item 5) through firewall
(Figure
1,
Item
10).
M9408DAA
3
4
5
6
2
7
1
11
12
13
5
10
10
9
9
8
Figure 1.
15-AMP Fuse and Jumper Lead Removal.
END OF TASK
TM 9-2320-272-23-3
0464
0464-2


Back to Top