INSTALLATION
1.
Connect Y-connector lead (Figure 2, Item 16) to ABS lamp lead No. 4 (Figure 2, Item 10).
2.
Connect Y-connector lead (Figure 2, Item 15) to yellow ABS main wiring harness lead (Figure 2, Item 17).
3.
Install Y-connector lead (Figure 2, Item 13) to R position (Figure 2, Item 12) on starter switch
(Figure 2, Item 11).
4.
Connect Y-connector lead (Figure 2, Item 4) to harness connector lead 54 (Figure 2, Item 1).
5.
Install starter switch (Figure 2, Item 11) on instrument cluster (Figure 2, Item 5) with lockwasher
(Figure 2, Item 9) and nut (Figure 2, Item 8).
6.
Install lever (Figure 2, Item 7) on starter switch (Figure 2, Item 11) with screw (Figure 2, Item 6).
7.
Install 3-AMP fuse (Figure 2, Item 2) in fuse holder (Figure 2, Item 14) and close cover (Figure 2, Item 3).
M9407DAA
5
6
7
9
8
10
11
13
15
14
12
4
3
2
1
18
16
17
Figure 2.
ABS 3-AMP Fuse and Y-Connector Lead Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install instrument cluster. (Volume 2, WP
0310)
2.
Connect battery ground cables. (Volume 2, WP
0350)
END OF TASK
END OF WORK PACKAGE
TM 9-2320-272-23-3
0463