TM-9-2320-272-23-3

TRUCK, 5-TON, 6X6, M939, M939A1, AND M939A2 SERIES TRUCKS (DIESEL)

TECHNICAL MANUAL; FIELD MAINTENANCE MANUAL; VOLUME 3 OF 5

SEPTEMBER 2012

  TM-9-2320-272-23-3 - Page 928 of 1469

INSTALLATION
1.
Connect jumper lead connector (Figure 2, Item 13) to power lead connector (Figure 2, Item 12) on firewall
(Figure 2, Item 10).
2.
Route jumper lead (Figure 2, Item 5) through firewall (Figure 2, Item 10), install grommet (Figure 2, Item 9)
and secure to harness lead (Figure 2, Item 11) with tiedown straps (Figure 2, Item 8) as necessary.
3.
Connect jumper lead connector (Figure 2, Item 6) to red lead connector (Figure 2, Item 1) on ABS main wiring
harness (Figure 2, Item 7).
4.
Install 15-AMP fuse (Figure 2, Item 2) in fuse holder (Figure 2, Item 4) and close cover (Figure 2, Item 3).
M9409DAA
3
4
5
6
2
7
1
11
12
13
5
10
10
9
9
8
Figure 2.
15-AMP Fuse and Jumper Lead Installation.
END OF TASK