INSTALLATION
NOTE
Install tiedown straps as required.
1.
Install lever (Figure 3, Item 2) in shift panel (Figure 3, Item 3) with washer (Figure 3, Item 17), pin
(Figure
3,
Item
1), and cotter pin (Figure 3, Item 4). Bend ends of cotter pin.
2.
Ensure grommet (Figure 3, Item 6) is positioned in firewall, and install cable clevis (Figure 3, Item 15) on lever
(Figure 3, Item 3) with washer (Figure 3, Item 14), clevis pin, and cotter pin (Figure
3,
Item
16). Bend ends
of cotter pin.
3.
Install shim (Figure 3, Item 8) and cable (Figure 3, Item 7) on shift panel (Figure 3, Item 3) with two screws
(Figure 3, Item 10) and two locknuts (Figure 3, Item 5).
4.
Install shift panel cover (Figure 3, Item 12) on shift panel (Figure 3, Item 3) with six screws (Figure 3, Item 11).
M6023DAA
11
12
10
9
8
13
14
15
16
17
1
2
3
4
5
6
7
Figure 3.
Winch Control Valve Cable.
TM 9-2320-272-23-4
0680
0680-4