DISASSEMBLY
WARNING
Solvent cleaning compound is flammable and toxic. Do not use near an open flame and
always have a fire extinguisher nearby when solvents are used. Use only in well-ventilated
places, wear protective clothing, and dispose of cleaning rags in approved container. Failure
to comply may result in damage to equipment, injury, or death to personnel.
1.
Thoroughly clean exterior of crane control valve (Figure 4, Item 3) with solvent cleaning compound (Volume
5, WP
0817).
2.
Remove eight snaprings (Figure 4, Item 5), pins (Figure 4, Item 2), and four handles (Figure 4, Item 1) from
base (Figure 4, Item 4) and crane control valve (Figure 4, Item 3). Discard snaprings.
M9678DAA
5
4
3
2
1
Figure 4.
Crane Gondola Control Valve Disassembly.
TM 9-2320-272-23-4
0698
0698-5