INSTALLATION - Continued
4.
Position o-ring (Figure 5, Item 4) on threaded end of adapter assembly (Figure 5, Item 3).
5.
Install check valve (Figure 5, Item 2) and adapter assembly (Figure 5, Item 3) on elbow (Figure 5, Item 5).
6.
Connect hose assembly (Figure 5, Item 1) to check valve (Figure 5, Item 2).
M9847DAA
5
3
2
4
3
2
1
Figure 5.
Hydraulic Reservoir Shutoff Modification Component Installation (M936/A1/A2).
7.
Position o-ring (Figure 6, Item 6) and adapter (Figure 6, Item 7) on front winch pump outlet port
(Figure
6,
Item
5) and install two swivel flanges (Figure 6, Item 4), four washers (Figure 6, Item 3), and screws
(Figure
6,
Item
2). Tighten screws 31 to 35 lb-ft (42 to 47 N·m).
8.
Install adapter assembly (Figure 6, Item 8) on adapter (Figure 6, Item 7).
9.
Position o-ring (Figure 6, Item 9) over threaded end of adapter assembly (Figure 6, Item 8) and install check
valve (Figure 6, Item 10) on adapter assembly.
10.
Install hose assembly (Figure 6, Item 1) on adapter (Figure 6, Item 11).
11.
Install hose assembly (Figure 6, Item 1) on check valve (Figure 6, Item 10).
TM 9-2320-272-23-5
0787
0787-6