TM 9-2320-280-34
6-4.
200 AMPERE ALTERNATOR (A0013036AA) TESTING AND REPAIR (Cont ’d)
2.
Remove four screws (4), lockwashers (5), and baffle plate (2) from drive end housing (7).
Discard
lockwashers (5).
3.
Slide five leads through grommet (3) and remove baffle plate (2) from drive end housing (7).
4.
Remove eight screws (15), six screws (16), and cover plate (1) from drive end housing (7).
NOTE
Lead 7 will fall free when hardware is removed.
5.
Remove two capscrews (9), positive leads (13), lead 7 (10), and an additional lead 4 (8) from
rectifier bridge (6).
6.
Remove nut (11), two positive leads (13), and spacer (12) from fuse holder (14).
6-22