TM 9-2320-328-13&P-1
0015-9
DRAFT
0015
Change 1
DIRECT TANK FILL
NOTE
Ensure vehicle is on level ground front to back and side to side before operating direct
tank fill auto operation.
Failure to comply may cause water tank to overfill.
1.
Remove cap (1) from direct tank fill inlet (2).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2.
Install siamese fitting (3) on direct tank fill inlet (2).
3.
Ensure bleeder valve (4) on siamese fitting (3) is in closed position.
4.
Connect either one or two 3 in. (7.6 cm) soft discharge hoses to siamese fitting (3) and positive water source.
5.
Open supply valve on positive water source.
HWT0028
HWT0027