TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 418 of 1318

TM 9-2320-328-13&P-1
0057-38
DRAFT
0057
Change 1
.
HWT0882A
.
Step 54.
Pull battery disconnect switch to off position (WP 0007).
Disconnect main wire harness
pump house wire harness connector.
With a test lead set, check for continuity across
pump house wire harness wire 2830 (red) from main wire harness pump house wire
harness connector, terminal 4 to pump house wire harness foam system shutoff control
valve connector, terminal 1.
.
a.
If there is continuity, repair wire 2830 in main wire harness if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0292).
.
b.
If there is no continuity, repair wire 2830 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0302).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top