TM 9-2320-328-13&P-1
0057-35
DRAFT
0057
Change 1
.
HWT0361
.
WARNING
.
ICON 26,66
.
•
Be sure to wear proper eye protection to prevent injury or death.
If air lines are
under pressure when they are disconnected, they can whip around and cause
injury to personnel.
Caution should be exercised when disconnecting air line
fittings.
•
Be sure to wear proper eye protection to prevent injury or death.
Air lines may be
under pressure when control valve is operated.
If under pressure and air lines are
disconnected, air lines may whip around and cause injury to personnel.
Caution
should be exercised when operating control valve with air lines disconnected.
.
NOTE
Air pressure is checked by disconnecting air lines at foam system shutoff valve and
observing air pressure escaping from air line, when foam system shutoff control valve is
activated.
Air will escape from the blue air line when FOAM SYSTEM switch is positioned
to the on position, and escape from the red air line when the FOAM SYSTEM switch is
positioned to the off position.
System air pressure may drop below 85 psi (586 kPa)
during this procedure.
.
Step 48.
Remove hose reel (WP 0247).
Disconnect air lines at foam system shutoff valve
(WP 0176).
While an assistant puts cab or pump operator’s panel FOAM SYSTEM
switch to ON and OFF positions (WP 0004), check if air pressure is present at foam
system shutoff valve.
.
If there is air pressure, replace foam system shutoff valve (WP 0176).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION