TM 9-2320-328-13&P-1
0057-27
DRAFT
0057
Change 1
.
HWT0878A
.
WARNING
.
ICON 3
.
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
.
Step 37.
Remove relay 6 (WP 0244).
With a test lead set, check for 22 to 28 VDC between cab
power distribution wire harness wire 2816 (red) at relay 6 connector, terminal 3 and a
known good ground.
.
If 22 to 28 VDC are not present, replace cab power distribution wire harness
and block (WP 0280).
.
Step 38.
Pull battery disconnect switch to off position (WP 0007).
With a test lead set, check for
continuity across cab power distribution wire harness wire 2845 (white) from relay 6
connector, terminal 4 to relay 9 connector, terminal 3.
.
a.
If there is continuity, replace relay 6 (WP 0244).
.
b.
If there is no continuity, replace cab power distribution wire harness
and block (WP 0280).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION