Step 17.
Install circuit breaker 6 (WP 0242).
Open pump operator’s panel (WP 0207).
Push
battery disconnect switch to on position (WP 0007).
Check for 22 to 28 VDC between
pump operator’s panel wire harness wire 2346 (red) at PANEL LIGHTS switch terminal
connector, and a known good ground.
If 22 to 28 VDC are not present, go to Step 19.
Step 18.
Pull battery disconnect switch to off position (WP 0007).
Check for continuity across
PANEL LIGHTS switch from terminal connector to terminal connector, when switch is
put to on position.
a.
If there is continuity, repair wire 1661 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
b.
If there is no continuity, replace PANEL LIGHTS switch (WP 0220).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION