TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 172 of 1390

TM 9-2320-328-13&P-2
0122-2
DRAFT
0122
HWT0412
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 3.
Pull battery disconnect switch
to off position (WP 0007).
Open pump operator’s
panel (WP 0207).
Cut wire 1661 (black) in pump operator’s panel wire harness
striplight butt splice connector from non-operating pump operator’s panel striplight.
Push battery disconnect switch to on position (WP 0007). Check for 22 to 28 VDC
between pump operator’s panel wire harness wire 1661 (black) at striplight butt splice
connector termination and known good ground.
If 22 to 28 VDC are not present, repair wire 1661 in pump operator’s panel
wire harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top