Step 15.
Put pump operator’s panel PANEL LIGHTS switch to off position (WP 0004).
Pull
battery disconnect switch to off position (WP 0007). Open pump operator’s
panel (WP 0207).
Disconnect pump operator’s panel wire harness striplight connector.
With a test lead set, check for continuity across pump operator’s panel wire harness
wire 3895 (black) from striplight connector terminal B, to a known good ground.
a.
If there is continuity, repair wire 1661 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
b.
If there is no continuity, repair wire 3895 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
HWT0697
Step 16.
Pull battery disconnect switch to off position (WP 0007).
Remove cab instrument
panel A (WP 0205).
Remove circuit breaker 6 (WP 0242). Check for continuity across
circuit breaker.
If there is no continuity, replace circuit breaker 6 (WP 0242).