TM 9-2320-328-13&P-2
0271-1
DRAFT
0271
FIELD LEVEL MAINTENANCE
SHUTOFF CONTROL VALVE REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
•
It is not necessary to remove cushion clips and wires attach to booster reel deflector.
•
Booster reel deflector shield shown with hose reel removed.
1.
Remove three nuts (1), lockwashers (2), six washers (3), three screws (4), and lower booster reel deflector (5)
from pump house frame (6).
Discard lockwashers.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2424
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Ties, Cable, Plastic (WP 0400, Item 26)
Lockwasher (3)
Preformed Packing (3)
Preformed Packing (1)
References
WP 0391, Fig. 3
Equipment Conditions
Air system drained (TM 9-2320-422-10)
Pump hose panels K and L removed (WP 0339)