TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 977 of 1390

TM 9-2320-328-13&P-2
0271-1
DRAFT
0271
FIELD LEVEL MAINTENANCE
SHUTOFF CONTROL VALVE REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
It is not necessary to remove cushion clips and wires attach to booster reel deflector.
Booster reel deflector shield shown with hose reel removed.
1.
Remove three nuts (1), lockwashers (2), six washers (3), three screws (4), and lower booster reel deflector (5)
from pump house frame (6).
Discard lockwashers.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2424
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Ties, Cable, Plastic (WP 0400, Item 26)
Lockwasher (3)
Preformed Packing (3)
Preformed Packing (1)
References
WP 0391, Fig. 3
Equipment Conditions
Air system drained (TM 9-2320-422-10)
Pump hose panels K and L removed (WP 0339)


Back to Top