TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 980 of 1390

TM 9-2320-328-13&P-2
0271-4
DRAFT
0271
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.
Install solenoid (16) on tank-to-pump valve (14) with two screws (15).
4.
Install tank-to-pump valve (14) on shutoff control valve manifold (9) with two screws (13).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Install cable ties as required.
5.
Connect tank-to-pump valve control wire harness connector (12) to tank-to-pump valve connector (11).
HWT2427
HWT2426