TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 985 of 1390

TM 9-2320-328-13&P-2
0272-3/(4 blank)
DRAFT
0272
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.
Install two door seals (7) on cover (8).
4.
Install door (6) on two hinges (2) with four screws (5), eight washers (4), and four locknuts (3).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Springs are under pressure.
Wear safety goggles and use caution when removing
or installing springs, snaprings, retaining rings, and other parts under spring
tension.
These parts can act as projectiles, resulting in serious injury to personnel.
5.
Install two springs (1) on hinges (2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install power cable assembly (SINCGARS) (WP 0260)
2.
Install radio/transmitter, amplifiers, and communication cables (TM 11-5820-890-10-1)
END OF TASK
END OF WORK PACKAGE
HWT1817
WARNING
ICON 26


Back to Top