TM 9-2320-328-13&P-2
0271-5/(6 blank)
DRAFT
0271
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6.
Install shutoff control valve manifold (9) on bracket (10) with two washers (8) and screws (7).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7.
Install booster reel deflector (5) on pump house frame (6) with three screws (4), six washers (3), three
lockwashers (2), and nuts (1).
END OF TASK
FOLLOW-ON MAINTENANCE
Install pump house panels L and K (WP 0339)
END OF TASK