Table 2-4. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 2. Test for battery voltage at lug D of magnetic starter relay.
Step 1.
Step 2.
Step 3.
Step 4.
Step 5.
With accessory/ignition switch ON, push start switch and at same time check for battery
voltage at lug D on starter relay.
a. If 19 Vdc are not present, go to test 4.
b. If voltage is present, go to step 2.
Set multimeter to RX1 scale. Check continuity between lug C on starter relay and ground.
a. If continuity is 1 ohm or less, go to step 3.
b. If continuity is greater than 1 ohm, disconnect ground lead at lug C. Repair or replace
ground lead (para. 4-51). Go to test 1, step 1.
Check for battery voltage at lug B of starter relay with start switch PUSHED.
a. If voltage is present, go to step 5.
b. If voltage is not present, go to step 4.
Check for battery voltage at lug A on starter relay. Voltage should always be present.
If voltage is not present, replace or repair lead 14 (para. 4-51). Go to test 1, step 1
and retest.
Check continuity of lead 214 between lug B on starter relay and pin 1 on starter solenoid.
If continuity is not present, replace or repair lead 214 (para. 4-51). Clean connections
before reinstalling lead. Ensure all connections are tight. Go to test 1, step 1 and retest.
2-81