Table 2-4. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 6. Remove lead 74 from pin A of start switch, turn accessory/ignition switch to ON position,
and check for battery voltage on contact end of lead 74.
a. If voltage is not present, disconnect lead 27 from accessory/ignition switch and check
continuity between lead 27 and its connection to lead 74.
b. If continuity is not found, replace or repair lead (para. 4-51). Reinstall lead 74 into
pin A.
Step 7. Attempt to start engine (TM 9-2320-361-10).
If starter does not engage engine, go to step 8.
Step 8. Remove lead 74 from pin A and lead 74A from pin B of start switch. Push start switch and
perform continuity check between pins A and B.
a. If continuity is not found, replace start switch (para. 4-8).
b. Check continuity of new switch before installation.
c. Reinstall lead 74A in pin B and lead 74 in pin A.
d. Push start switch. Starter should turn engine.