TM-9-2320-361-24-1

2-1/2 TON, 6X6, M44A2 SERIES TRUCKS

TECHNICAL MANUAL; FIELD AND SUSTAINMENT MAINTENANCE PART 1 OF 2

AUGUST 2006

  TM-9-2320-361-24-1 - Page 202 of 1176

MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. STARTER MOTOR
OPERATES, BUT
ENGINE CRANKS
SLOWLY (Contd)
3. With engine stop control
handle pulled out, crank
engine for 30 seconds
(TM 9-2320-361-10). Voltage
reading should be 19 VDC or
more during cranking.
4. Disengage engine stop control
handle (TM 9-2320-361-10).
1. If battery voltage is not
satisfactory, go to WP 0012 00,
table 1, malfunction 1, test 1.
2. If battery voltage is satisfactory,
replace starter motor and solenoid
assembly (WP 0088 00).
If engine still cranks slowly, replace
batteries (WP 0127 00).
TM 9-2320-361-24-1
0012 00
0012 00-18
BATTERY AND CHARGING SYSTEM TROUBLESHOOTING (Contd)
Table 2. Starting System Troubleshooting Procedure (Contd).
CHARGING SYSTEM (60 AMP)
POWER
ACCESSORY
SWITCH
SLAVE
RECEPTACLE
POS
NEG
STARTER
RELAY
STARTER
SOLENOID
10
14
74A
74
27
27
1
11
25
49
50
6
2
68
7
1
214
568
74B
B
D
C
A
B
A
14
32
VOLTMETER
60-AMP
ALTERNATOR
STARTER
MOTOR
12-VOLT
BATTERY
15-AMP
HORN
CIRCUIT
BREAKER
INPUT FIELD VOLTAGE
+28 VDC OUTPUT
RH GROUND FRAME
START
SWITCH
D
C
BA


Back to Top