TM 9-2320-361-34
15-20. 115-VOLT RECEPTACLE REPLACEMENT
THIS TASK COVERS:
a. Removal
b. Installation
INITIAL
SETUP
APPLICABLE MODELS
M185A3 and M109A3
EQUIPMENT CONDITION
. Parking brake set (TM 9-2320-361-10).
●
TOOLS
General mechanic’s tool kit
●
(Appendix B, Item 1)
Tool kit, electrical (Appendix B, Item 2)
REFERENCES (TM)
TM 9-2320-361-10
TM 9-2320-361-20
TM 9-2320-361-34P
Battery
-
ground cable disconnected
(TM 9-2320-361-20).
Safety switch in OFF position
(TM 9-2320-361-10).
a. Removal
NOTE
Tag wires, leads, terminals, and cables for installation.
1. Remove cap (1), clip (2), and cover (3) from base (5) on van wall (4).
2. Remove two screws (7) from receptacle (6) and retainers (8).
3. Pull receptacle (6) away from van wall (4).
4. Loosen three screws (10) and remove six wire
leads
(9) from receptacle (6).
5. Remove receptacle (6) from van wall (4).
6. Remove two retainers (8) from base (5).
1. Install two retainers (8) on base (5).
2. Install six wire leads (9) on receptacle (6) by tightening three screws (10).
3. Install receptacle (6) on two retainers (8) with two screws (7).
4. Install cover (3), clip (2), and cap (1) on base (5).
b. Installation
15-74