NOTE
If outriggers or stabilizers fail to operate, complete steps 12-17.
11.
Move HV5 bypass valve to manual override position (7).
12.
Move ground rod driver switch (8) to manual ON position.
13.
Operate outriggers twice. Outriggers remain extended.
14.
Extend outrigger stabilizers (WP 0013).
15.
Extend stabilizers (WP0013)
16.
Position HV5 bypass valve (7) out of manual override.
17.
After one complete cycle at idle, hydraulic system is ready for normal operations.
END OF TASK