TM 9-2320-440-13&P
0027-4
0027
HOOK ARM DOES NOT LOAD IN MANUAL MODE (CONTINUED)
THAAD0700
WARNING
The THAAD hydraulic system operates up to 3,100 psi (21,374 kPa).
Never
disconnect any hydraulic line or fitting without first dropping system pressure to
zero.
Failure to comply may result in serious injury or death to personnel.
CAUTION
Engine speed must be at idle before using hydraulic select switch.
Failure to
comply may result in damage to equipment.
Step 4.
Disconnect hose 2882 from fitting at rear of main frame. Install pressure gage with tee
fitting between hose 2882 and main frame bulkhead fitting. Soldier A starts
engine (
while Soldier B attempts to load hook arm using
emergency procedure (WP 0016), check pressure gage and note reading. Shut off
engine (
Remove pressure gage and tee fitting. Install hose
2882 (WP 0119).
If 3,100 psi (21, 374 kPa) are not present, replace directional control valve
(WP 0125).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TM 9-2320-347-10)
TM 9-2320-347-10)