TM 9-2320-440-13&P
0026-5
0026
WORK LIGHT(S) DO NOT OPERATE (CONTINUED)
THAAD0045
WARNING
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment or
severe burns or electrical shocks to personnel.
Step 8.
Remove work light lamp (WP 0091). Check for continuity across work light lamp.
If there is no continuity, replace work light lamp (WP 0091).
Step 9.
Check for continuity across work light internal ground wire from work light lamp to work
light connector, terminal B.
If there is no continuity, repair work light internal ground wire
(TM 9-2320-325-14&P).
Step 10.
Remove work light switch (WP 0091). Check for continuity across work light internal
power wire from work light connector, terminal A to work light switch wire termination.
a.
If there is continuity replace work light switch (WP 0091).
b.
If there is no continuity, repair work light internal power wire
TM 9-2320-325-14&P