TM 9-2320-440-13&P
0026-1
0026
FIELD LEVEL MAINTENANCE
WORK LIGHT(S) DO NOT OPERATE
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WORK LIGHT(S) DO NOT OPERATE
THAAD0041
Step 1.
Turn work lights on (WP 0005). Check if MRP and outrigger control station work lamps
and work light operate.
a.
If MRP and outrigger control station work lamps and work light do not
operate, go to Step 11.
b.
If MRP and outrigger control station work lamps operate and work light
does not operate, go to Step 6.
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0183, Item 25)
Materials/Parts
None
Personnel Required
MOS 63B Wheeled vehicle mechanic
References
TM 9-2320-325-14&P
WP 0005
WP 0058
WP 0090
WP 0091
Equipment Conditions
Engine OFF (
Parking brake applied (
Wheels chocked (
TM 9-2320-347-10)
TM 9-2320-347-10)
TM 9-2320-347-10)