TM 9-2320-440-13&P
0030-3
0030
LHS CAB CONTROL FAILS SELF TEST OR NO VIM HEART BEAT INDICATION (CONTINUED)
THAAD0491
NOTE
Each VIM has two HEART BEAT indicator lights. The first HEART BEAT indicator light will
steadily illuminate and the second HEART BEAT indicator light will flash when the VIM is
operating correctly.
Step 3.
Check if one of the HEART BEAT indicator lights is steadily illuminated on both VIMs.
If one of the HEART BEAT indicator lights is not illuminated on both VIMs, go
to Step 25.
Step 4.
Check if the second HEART BEAT indicator light is flashing on both VIMs.
If the second HEART BEAT indicator light is not flashing on both VIMs, go to
Step 10.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION