TM-9-2330-227-14-P

SEMITRAILER, VAN: SHOP, 6-TON, SINGLE AXLE, M146

TECHNICAL MANUAL; OPERATOR’S, ORGANIZATIONAL, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

JUNE 1985

  TM-9-2330-227-14-P - Page 154 of 576

TM 9-2330-227-14&P
CONNECTOR RECEPTACLE, 24-VOLT - CONTINUED
INSTALLATION - CONTINUED
TASK ENDS HERE
CONNECTOR RECEPTACLE, 110-VOLT
This task covers:
a. Removal (page 4-76)
b. installation (page 4-77)
INITIAL SETUP
Tools
Personnel Required
Handle, ratchet, 1/2-inch drive
One
Screwdriver, flat-tip, 3/16-inch
Socket, 1/2-inch drive, 1/2-inch
ACTION
LOCATION
ITEM
REMARKS
WARNIN G
Contact with live 110-volt electrical wires could result in serious injury or death. Make
sure power source is disconnected before performing maintenance on the electrical
system.
REMOVAL
1.
Connector
Four screws (2)
Using 1/2-inch socket and ratchet handle,
receptacle (1)
and Iockwashers (3)
unscrew and take out.
2.
Outside front
Connector
Pull away from wall just far enough to
wall (4)
receptacle (1)
reach behind with 3/16-inch flat-tip
screwdriver.
NOT E
Tag wires to aid in installation (page 4-4). If circuit marker bands are missing or not
readable, replace (page 4-66).
3.
Connector
Two screws (5)
Using 3/16-inch flat-tip screwdriver,
receptacle (1)
unscrew part way.
4.
Connector
Two wires (6)
a. Pull out wires (6).
recptacle (1) and
b. Take off receptacle (1).
wire harness (7)
4-76


Back to Top