TM 9-2330-334-13&P
CIRCUIT BREAKER, MODULE,
0057 00
AND CONNECTOR REPLACEMENT-Continued
Change 1
0057 00-2
CIRCUIT BREAKER REMOVAL
NOTE
•
Tag connections and connection points prior to disconnecting.
•
Remove plastic cable ties as required.
•
Circuit breakers 1, 2, 3, 5, 6, and 7 removed the same way. Circuit breaker position 1 shown.
•
Perform the following step on circuit breakers 1, 2, 3, 5, 6, and 7.
1.
Remove nut (1), lockwasher (2), and terminal lug (3) from circuit breaker “BAT” terminal stud (4).
Discard lockwasher.
NOTE
Perform the following step on circuit breakers 4 and 8.
2.
Remove nut (1), lockwasher (2), and two terminal lugs (3) from circuit breaker “BAT” terminal stud
(4). Discard lockwasher.
3.
Remove circuit breaker (5) from circuit breaker base (6).