TM 9-2330-334-13&P
CIRCUIT BREAKER, MODULE,
0057 00
AND CONNECTOR REPLACEMENT - Continued
Change 1
0057 00-10
12 VDC CONNECTOR INSTALLATION
NOTE
All 12 VDC connector wires are installed the same way.
1.
Install 12 VDC connector (16) on voltage converter box cover (30) with two bolts (29), lockwashers
(28), and nuts (27).
2.
Position wire (26) on position 1WHT on 12 VDC connector (16).
3.
Tighten screw (25) at position 1WHT on 12 VDC connector (16).
4.
Perform the previous two steps on remaining wires.