TM 9-2330-334-13&P
CIRCUIT BREAKER, MODULE,
0057 00
AND CONNECTOR REPLACEMENT - Continued
Change 1
0057 00-8
MODULE INSTALLATION - Continued
2.
Strip approximately 1/4 in. (0.6 cm) of insulation from wire (18).
3.
Solder wire (18) to pin E on 24 VDC connector (19).
4.
Position wire (17) at position BRN on 12 VDC connector (16).
5.
Tighten screw (15) at position BRN on 12 VDC connector (16).
6.
Install wire (13) on right ground stud (14) with lockwasher (12) and nut (11).
7.
Install wire (9) on circuit breaker CB7 “BAT” terminal stud (10) with lockwasher (8) and nut (7).