TM 9-2330-334-13&P
CIRCUIT BREAKER, MODULE,
0057 00
AND CONNECTOR REPLACEMENT - Continued
Change 1
0057 00-12
24 VDC CONNECTOR INSTALLATION
NOTE
All 24 VDC connector wires are installed the same way.
1.
Install 24 VDC connector (19) and cover (35) on voltage converter box cover (30) with four screws (34),
lockwashers (33), and nuts (32).
2.
Strip approximately 1/4 in. (0.6 cm) of insulation from wire (31).
3.
Solder wire (31) to ground pin on 24 VDC connector (19).
4.
Perform the previous two steps on remaining wires.