INSTALLATION - Continued
1
2
3
Figure 4.
Emergency Brake Air Line Installation.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open flame and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
CAUTION
Use sealing compound sparingly and only on threads. Do not apply sealing compound on
hose connections. Damage to equipment may result.
2.
Apply sealing compound on threads of fitting (Figure 5, Item 2).
1
2
3
Figure 5.
Emergency Brake Air Line Installation.
3.
Install fitting (Figure 5, Item 2) on emergency air line (Figure 5, Item 3).
4.
Install gladhand (Figure 5, Item 1) on fitting (Figure 5, Item 2).
5.
Install bulkhead fitting (Figure 6, Item 5) on bracket (Figure 6, Item 8) with nut (Figure 6, Item 4).
TM 9-2330-342-23&P
0073
0073-4