TM-9-2330-356-14

SEMITRAILER, TANK: 5000 GALLON, BULK HAUL, SELF LOAD/UNLOAD M967 AND M967A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, AUTOMOTIVE M969 AND M969A1; SEMITRAILER, TANK: 5000 GALLON, FUEL DISPENSING, UNDER/OVERWING AIRCRAFT M970 AND M970A1

TECHNICAL MANUAL; OPERATOR’S, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

OCTOBER 1990

  TM-9-2330-356-14 - Page 197 of 528

TM 9-2330-356-14
(2)
Voltmeter and/or Pump Pressure Gage.
NOTE
Put suitable container under tube connec-
tions to catch fuel.
(a)
Remove electrical lead (fig. 4-41) from
rear of voltmeter, and/or tube connector (fig. 4-40) from
rear of pump pressure gage.
(b)
Remove two nuts and brackets that
retain meter or gage to control panel.
(c)
Remove meter or gage from panel.
(d)
Remove snubber from pump pressure
gage.
(e)
Install new meter or gage in reverse
order of steps
(a)
through
(c).
(f)
Cleanup all fuel spills.
(3)
Tachometer and/or Hourrneter.
(a) Tag
and disconnect electrical leads
(fig. 4-41) from rear of tachometer and/or disconnect
connector in hourmeter line.
(b)
Remove three screws and nuts from
hourmeter and pull meter out from front of control panel.
(c)
Remove two nuts and bracket that
retains tachometer to control panel and pull meter out
from front of panel.
(d)
Install new meter in reverse order of
steps
(a)
and (b), being careful to reconnect leads exactly
as they were connected to the meter that was removed.
Figure 4-40. Pressure Gages in Control Panel.
TA099795
4-61


Back to Top