TM 9-2330-356-14
(2)
Voltmeter and/or Pump Pressure Gage.
NOTE
Put suitable container under tube connec-
tions to catch fuel.
(a)
Remove electrical lead (fig. 4-41) from
rear of voltmeter, and/or tube connector (fig. 4-40) from
rear of pump pressure gage.
(b)
Remove two nuts and brackets that
retain meter or gage to control panel.
(c)
Remove meter or gage from panel.
(d)
Remove snubber from pump pressure
gage.
(e)
Install new meter or gage in reverse
order of steps
(a)
through
(c).
(f)
Cleanup all fuel spills.
(3)
Tachometer and/or Hourrneter.
(a) Tag
and disconnect electrical leads
(fig. 4-41) from rear of tachometer and/or disconnect
connector in hourmeter line.
(b)
Remove three screws and nuts from
hourmeter and pull meter out from front of control panel.
(c)
Remove two nuts and bracket that
retains tachometer to control panel and pull meter out
from front of panel.
(d)
Install new meter in reverse order of
steps
(a)
and (b), being careful to reconnect leads exactly
as they were connected to the meter that was removed.
Figure 4-40. Pressure Gages in Control Panel.
TA099795