TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 346 of 783

TM 9-2350-260-20-1-3
ELECTRICAL WIRING HARNESS AND CABLE CONNECTOR REPAIR
Female Receptacle Repair (Sheet 1 of 3)
TOOLS: Electrical connector repair tool kit
Soldering gun
Slip joint pliers with plastic jaw inserts
Diagonal cutting pliers
Pocketknife
Multimeter
SUPPLIES: Silicone compound (Item 32, Appendix D)
Electricians tape (Item 58, Appendix D)
Jumper wire
Heat-shrink tubing
REFERENCE: TM 9-2350-260-10
PRELIMINARY PROCEDURES: Disconnect three battery ground straps (page 10-294)
Loosen or remove cable clamps as required
Disconnect connectors at each end of affected cable
1.
Manually thread grommet retaining nut (A) from plug
assembly (B).
2.
Slide grommet retaining nut (A) back along cable
(C).
3.
Using slip joint pliers, work grommet (D) back and
forth and out of plug assembly (B).
4.
Using remover, push contact (E) with damaged wire
out of back of plug assembly (B).
5.
Using diagonal cutting pliers, cut wire from contact (E).
Throw away contact (E).
6.
Pulling cut wire out of grommet (D), use diagonal cutting pliers to shorten wire about 6 inches.
Fasten new end of cut
wire to cable (C) with electrical tape (Item 58, Appendix D).
Go on to Sheet 2
10-334


Back to Top