TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 336 of 783

TM 9-2350-260-20-1-3
ELECTRICAL WIRING HARNESS AND CABLE CONNECTOR REPAIR
Terminal Connector Repair (Sheet 1 of 2)
TOOLS: Electrical connector repair tool kit
Diagonal cutting pliers
Heat gun
Pocketknife
Multimeter
SUPPLIES: Heat-shrink tubing
PRELIMINARY PROCEDURES: Disconnect three battery ground straps (page 10-294)
Loosen or remove cable clamps as required
1.
Using knife, slit heat-shrink tubing (A) along its entire
length.
Throw heat-shrink tubing (A) away.
3.
Using hand wire stripper, strip insulation from cable
(C) equal to well depth in terminal (B).
2.
Using diagonal cutting pliers, cut terminal (B) from
cable (C).
Throw terminal (B) away.
Go on to Sheet 2
TA147356
10-324


Back to Top