TM 9-2350-260-20-1-3
ELECTRICAL WIRING HARNESS AND CABLE CONNECTOR REPAIR
Female Connector With Washer (12 Gage Cable) Repair (Sheet 1 of 1)
TOOLS: Electrical connector repair tool kit
Diagonal cutting pliers
Multimeter
PRELIMINARY PROCEDURES: Disconnect three battery ground straps (page 10-294)
Loosen or remove cable clamps as required
1.
Slide shell (A) back along cable (B).
3.
Using hand wire stripper, strip insulation from cable
(B) equal to well depth in terminal (C).
4.
Slide new washer (D) onto stripped cable end (E)
back to cable insulation.
2.
Using diagonal cutting pliers, cut terminal (C) and
washer (D) from cable (B).
Throw terminal (C) and
washer (B) away.
5.
Insert stripped cable end (E) into well in terminal (C).
6.
Using crimping tool, crimp terminal (C).
7.
Slide shell (A) forward until tight against washer (D).
8.
Using multimeter, check continuity of repaired circuit.
9.
Tighten or install cable clamps as required.
10. Connect three battery ground straps (page 10-294).
End of Task
TA147364
10-332