TM 9-2350-260-20-1-3
ELECTRICAL WIRING HARNESS AND CABLE CONNECTOR REPAIR
Terminal Connector Repair (Sheet 2 of 2)
4.
Slide new heat-shrink tubing (D) onto and back
along cable (C).
5.
Slide new terminal (B) over stripped cable end (E)
and onto cable (C).
7.
Slide heat-shrink tubing (D) over crimps (F) and (G).
8.
Using heat gun, shrink tubing (D).
9.
Using multimeter, check continuity of repaired circuit.
10. Tighten or install cable clamps as required.
11. Connect three battery ground straps (page 10-294).
6.
Using crimping tool, crimp terminal (B) at (F) and
(G).
End of Task
TA147357
10-325