TM 9-2350-260-20-1-3
ELECTRICAL WIRING HARNESS AND CABLE CONNECTOR REPAIR
Female Plug Repair (Sheet 2 of 3)
5.
Using diagonal cutting pliers, cut wire from contact
(E).
Throw away contact (E).
6.
Pulling cut wire out of grommet (D), use diagonal
cutting pliers to shorten wire about 6 inches.
Fasten
new end of cut wire to cable (C) with electricians
tape.
9.
Push new contact (E) into hole in back of plug
assembly (B) far enough so it will remain standing.
10. Push jumper wire end through grommet retaining nut
(A) and then through hole in grommet (D).
7.
Using hand wire stripper, strip insulation from jumper
wire equal to depth of contact solder well (F).
8.
Placing connector face down on flat surface, apply a
small amount of silicone (Item 32, Appendix D) to
empty holes on back of plug assembly (B) and on
front of grommet (D).
Go on to Sheet 3