TM 9–2350–311–20–2
Change 2
5–37
b.
Disassembly
1
Remove eight self-locking nuts (11) and eight machine bolts (12) from dust shield (4). Discard self-locking
nuts.
NOTE
Step 2 applies to M178 mount configuration. Step 3 applies to M182 mount configuration.
2
Separate dust shield (4), mechanical felt (13), gasket (14), and retainer (15). Discard mechanical felt and
gasket.
3
Separate dust shield (4), two gaskets (16), gasket (17), and mechanical felt (18). Discard gaskets and me-
chanical felt.
c.
Inspection and Repair
1
Inspect dust shield (4) for distortion. Repair or replace if damaged or distorted.
2
Inspect retainer (15). Replace if distorted or if tab is worn.
11
12
13
14
15
16
17
18
M182 MOUNT CONFIGURATION
M178 MOUNT CONFIGURATION
11
4
4
12
16