TM 9–2350–311–20–2
Change 2
7–17/(7–18 blank)
7–4
ACTUATING VALVE
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools
Artillery and turret mechanic’s tool kit
(SC 5180–95–CL–A12)
Utility pail (item 7, Appx H)
Materials/Parts
Caps and plugs (item 7, Appx D)
Lockwashers (2) (item 95, Appx G)
Equipment Condition
Discharge hydraulic pressure (para 6–3)
a.
Removal
CAUTION
All hydraulic lines and ports must be capped to prevent contaminants from entering the hydraulic
system and causing internal damage to hydraulic components.
NOTE
Have a utility pail available to catch hydraulic fluid from valve and connectors.
Dispose of hydraulic fluid in accordance with local regulations.
1
Disconnect four tubes (1).
2
Remove two cap screws (2), two lockwashers (3), and actuating valve assembly (4). Discard lockwashers.
b.
Installation
1
Install actuating valve assembly (4) using two new lockwashers (3) and two cap screws (2).
2
Connect four tubes (1).
3
1
2
4